Times
ENTRY and EXIT times are in seconds (maximum 255 seconds). Alarm
delay, PATROL and ALARM times are in minutes (maximum 99 minutes).
Add. Partition 1 times Data
112 Exit Time in secondsu
113 Entry Time in seconds u
114 Arming Delay in minutes u
Add. Partition 2 times Data
115 Exit Time in secondsu
116 Entry Time in seconds u
117 Arming Delay in minutes u
Add. Partition 3 times Data
118 Exit Time in secondsu
119 Entry Time in seconds u
120 Arming delay in minutes u
Add. Partition 4 times Data
121 Exit Time in secondsu
122 Entry Time in seconds u
123 Arming Delay in minutes u
Add. Patrol time Data
124 Patrol Time in minutes u
Add. Alarm time Data
125 Alarm Time in minutes u
Telephone Numbers (Addresses 126 through 157)
When programming a Telephone Number ----use key to insert pauses
of 2 seconds, and key key to cancel errors.
KEYS
CALL
TYPE
EXTENDED CHECK-SUM
Ademco
Slow 10bps
ON = Extended
OFF = Not Extended
-
Ademco
Fast 14 bps
-
ON = Check-Sum
OFF = No Check-Sum
Franklin
20bps
- -
Radionics
40bps
- -
Scantronics
10bps
- -
Customized - -
ContactID - -
PROGRAMMING FROM KEYPAD 97