Hour and
Minutes
Program the time (hour and minutes) for the Test event.
Delay Program the number of days that must expire before activation of the Test
event. The delay will start when the programming phase, accessed by the
Installer Code PIN, is quitted.
+
The programmed Delay (numbers of days) will be applied each time the
programming phase, accessed by the Installer Code PIN, is quitted.
For example, if the programmed Interval is 7 days, with a Delay of 1 day,
and the programming phase, accessed by the Installer Code PIN, is quit-
ted on a Monday, the Test event will be activated every Tuesday at the
programmed time. However, if the programming phase is accessed by the
Installer Code PIN on a Tuesday, the Test event will be activated every
Wednesday at the programmed time, and so forth.