10. Press to save parameter 62 and step to parameter 63 for Attributes
Zone 1 (PHASE 2).
11. Program the Attributes for zone 1 (accepted keys 1 through 5).
12. Press to save parameter 63 and step to parameter 64 for Alarm cy-
cles Zone 1 (PHASE 2).
13. Program the number of Alarm cycles for zone 1 (accepted values 0
through 15).
14. Press to save parameter 64 and step back to PHASE 1 step 3.
If is pressed at step 3 ----programming will be quitted. If is
pressed after step 3 ----the current parameter will not be saved and the
control panel will step back to PHASE 1 step 3.
+
PRESS THE ENTER KEY TO SAVE THE ENTERED PARAMETER VALUE.
Example C
1. Enter the Installer PIN.
LED L7 will flash slowly to signal access to programming ----PHASE 1.
2. Press .
3. Enter a valid Address (e.g. event 325 "SUPERKEY 1" ----refer to "User
Manual").
4. Press ----PHASE 2 ----LED L6 ON: this is a multi-field parameter with
three fields: Calls - Event Code - Voice Message. The first field is for the
telephone numbers that will be called when the event occurs.
5. Program the telephone numbers (accepted keys 1 through 8).
6. Press to save the data in the "Calls" field and step to the "Event
Code" field (PHASE 2).
7. Enter the 2 digit event code for the "SUPERKEY 1" event (accepted keys 0
through 9).
8. Press to save the data in the "Event Code" field and step to the
"Voice Message" field (accepted keys 1 through 8 ----PHASE 2).
9. Select the voice message for the "SUPERKEY 1" event (accepted keys 1
through 8 or key 9 for no message ----refer to User Manual).
10. Press to save the data in the "Voice Message" field and step back to
PHASE 1 step 3.
PROGRAMMING FROM KEYPAD 89